Micropatterned Substrates with Improved Uniformity of Deposition for DNA Microarrays
Jose M.
Moran-Mirabal, Christine P. Tan, Eric O. Williams, David M. Lin,
Harold G.
Craighead
Biomolecular arrays have become a core technology used in numerous fields for parallel analysis. However, it has become obvious that current microarrays are hindered by methodological and technological barriers that limit their sensitivity, reproducibility, and therefore their utility. A fundamental problem with DNA microarrays is the relative insensitivity in detecting weakly expressed transcripts; this is especially significant when examining gene expression in complex tissues. While it has been proposed that a marked improvement in the detection limit of microarrays could be achieved if a uniform DNA layer can be spotted [2], the issue of its implementation has not been fully addressed. In an effort to resolve this problem, we have fabricated micropatterned substrates for the uniform deposition of DNA with a polymer lift-off technique [3]. We pursued a methodology compatible with existing microarray technologies, which constrained the substrate area where the probe DNA were spotted. This yields a uniform layer of deposited DNA and improves the microarray data reproducibility between replicates on a single slide, and also across multiple slides.
Micropatterned substrates were fabricated by vapor-deposition of a
conformal polymer coating on glass substrates, followed by patterning with
photolithography and oxygen plasma reactive ion etching (Fig. 1). This process
defined the exposed areas of the underlying substrate. The fabricated
substrates were spotted with probe oligonucleotides in a conventional
microarrayer. The polymer coating was then peeled-off from the surface leaving
behind only the material spotted within the openings. The substrates were later
hybridized and processed in the same way as a conventional microarray glass
slide.
To test deposition uniformity, fluorescently-labeled oligonucleotide
probes were spotted on microfabricated substrates and control slides, and then
imaged with confocal microscopy. It was observed that constraining the
available area to the patterned openings facilitated the uniform deposition of
DNA, reducing or eliminating the donuts seen with commercial glass substrates
(Fig. 2). To test the impact on sensitivity and reproducibility, we used
successive dilutions of an unlabeled gene pool probe, which functioned as a
universal positive control binding to RNA from any murine tissue sample [4]. As
expected from previous reports [4], no signal was observed on control slides
when the DNA was spotted at concentrations below 5 pg/l. This provides indication that constraining
the deposition surface as well as providing a more hydrophobic region outside the
exposed glass areas, produced uniform probe DNA deposition patterns and could
dramatically improve the reproducibility of microarray data.
Collectively, these results indicate that arrays spotted on microfabricated substrates are more reproducible than standard arrays. Furthermore, the presence of the polymer during the spotting procedure reduces the background present in inter-spot areas. The combined improvements could allow for faster identification of differentially expressed transcripts in complex tissues. Experiments are under way to evaluate the sensitivity of these microfabricated arrays with real tissue samples.

Figure 1. Fabrication, DNA patterning and hybridization for polymer lift-off microarrays.

Figure 2. Fluorescently-labeled oligonucleotides observed with confocal microscopy: a, b) Commercial glass microarrays with most of the signal on the outer rim; c, d) Our microfabricated arrays with uniformly spread signal.
References:
1. Quantitative monitoring of gene expression patterns with a complementary DNA microarray. M. Schena, D. Shalon, R.W. Davis, and P.O. Brown. Science 270, 467-470. (1995).
2. Microarray optimizations: increasing spot accuracy and automated identification of true microarray signals. P.H. Tran, D.A. Peiffer, Y. Shin, L.M. Meek, J.P. Brody, and K.W. Cho. Nucleic Acids Res 30, e54. (2002).
3. Topographical patterning of chemically sensitive biological materials using a polymer-based dry lift off. B. Ilic and H.G. Craighead. Biomedical Microdevices 2, 317-323. (2000).
4. Normalization for cDNA microarray data: a robust composite method addressing single and multiple slide systematic variation. Y.H. Yang, S. Dudoit, P. Luu, D.M. Lin, V. Peng, J. Ngai, and T.P. Speed. Nucleic Acids Res 30, e15. (2002).